Validación Estructural de una Vivienda de Interés Social Mediante, Estudios Analítico-Experimentales

Main Article Content

Melisa Herrera
Christian Gómez
Klever Parra
Diego Arévalo
Luis Hernández
Patricia Placencia

Abstract

In the present investigation, a housing of social interest was validated structurally, which has an innovative constructive system of sandwich panels.To validate the house, several experimental studies were carried out, including field tests and laboratory tests, both on the materials and on the housing prototype. For the tests, the ASTM standards and the ACI-318 code were used, under the technical direction of the Housing Research Center of the National Polytechnic School. From the studies carried out, curves of capacity, rigidity, stresses and modulus of elasticity of the materials were obtained, showing that the house presents a good behavior before vertical and lateral loads (seismic actions). Additionally, an analytical study was carried out with the help of a three-dimensional mathematical model to know the distribution of efforts in the house and compare them with the efforts obtained experimentally.The obtained results showed that the house is apt to resist gravitational and lateral solicitations that the NEC-15 standard requires

Downloads

Download data is not yet available.

Metrics

Metrics Loading ...

Article Details

How to Cite
Herrera, M., Gómez, C., Parra, K., Arévalo, D., Hernández, L., & Placencia, P. (2019). Validación Estructural de una Vivienda de Interés Social Mediante, Estudios Analítico-Experimentales. INGENIO, 2(1), 11–23. https://doi.org/10.29166/ingenio.v2i1.1631
Section
Artículos
Author Biographies

Melisa Herrera, National Polytechnic School

Facultad de Ingeniería Civil y Ambiental

Centro de Investigación de la Vivienda

Christian Gómez, National Polytechnic School

Facultad de Ingeniería Civil y Ambiental

Centro de Investigación de la Vivienda

Klever Parra, National Polytechnic School

Facultad de Ingeniería Civil y Ambiental

Centro de Investigación de la Vivienda

Diego Arévalo, National Polytechnic School

Facultad de Ingeniería Civil y Ambiental

Centro de Investigación de la Vivienda

Luis Hernández, National Polytechnic School

Facultad de Ingeniería Civil y Ambiental

Carrera de Ingeniería Civil

Patricia Placencia, National Polytechnic School

Facultad de Ingeniería Civil y Ambiental

Carrera de Ingeniería Civil

References

Iza M., Modelación de un sistema estructural alternativo, prefabricado de bajo costo, para una vivienda de dos pisos. (Paneles de metálicos con inyección de poliuretano de alta densidad), Quito, Pichincha, 2012, p. 200.

Abeysinghe C., Thambiratnam D. and Perer N. A, Flexural performance of an innovative Hybrid Composite Floor Plate System, 2013, p. 26.

Bournas D., Torrisi G., Crisafulli F. and Pavese A., Experimental Investigation and Analytical Modeling of Prefabricated Reinforced Concrete Sandwich Panels, vol. 14, Portugal, 2012.

NEC-15 Capítulo 9, NEC-SE-VIVIENDA: Viviendas de hasta 2 pisos con luces de hasta 5 metros, 2015.

KUBIEC, KUTÉRMICO paneles tipo sanduche con aislamiento termoacústico, Quito, Pichincha, 2015.

ASTM C271, Standard Test Method for Density of Sandwich Core Materials., ASTM, 2017.

ASTM C393, Standart Test Method for Core Shear Properties of Sandwich Constructions by Beam., ASTM, 2017.

ASTM C365, Standart Test Method for Flatwise Compressive Strength of Sandwich Constructions, ASTM, 2017.

ASTM C364, Standart Test Method for Edgewise Compressive Strength of Sandwich Constructions, ASTM, 2017.

ASTM E72, Standart Test Method of Conducting Strength Tests of Panels for Building Constructions, ASTM, 2017.

A. C. I. ACI 318S, Requisitos de Reglamento para Concreto Estructural y Comentario, Estados Unidos, 2014.

NEC-15 Capítulo 1, NEC-SE-CG: Cargas no sísmicas, 2015.

NEC-15 Capítulo 2, NEC-SE-DS: Peligro Sísmico y Requisitos de Diseño Sismo Resistente, 2015.

Parra G. and Sarango J., Análisis estadístico del periodo experimental de vibración de edificios aporticados de hormigón armado en el Distrito Metropolitano de Quito., Quito, Pichincha, 2016.

Guillier B., Chatelain J. L., Tavera H., H. Perfettini, Ochoa A. and Herrera B., Establishing Empirical Period Formula for RC Buildings in Lima, Peru: Evidence for the Impact of Both the 1974 Lima Earthquake and the Application of the Peruvian Seismic Code on High-Rise Buildings., vol. 85(6), Seismological Research Letters, 2014, pp. 1308-1315.

Unión Europea para la Idoneidad Técnica en la Construcción, "Informe Técnico de la UEAtc para la Evaluación de las Obras Realizadas con Paneles Sándwich de Espuma de Poluiretano sin CFC.," 1996.